Tdk NB-59S-09S-0 Manuel d'utilisateur Page 2

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 4
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 1
(1/3)
002-03 / 20120316 / ef441_nb.fm
All specifications are subject to change without notice.
Ultrasonic Nebulizer Units
Incorporate Type
NB Series
The TDK ultrasonic humidifier unit was the first such product in the
world to be developed. There is an increasing need for indoor
humidification due to the proliferation of clean air heat pumps and
central heating systems.
When the appropriate amount of humidity is added as determined
by the relationship between humidity and sensible temperature
(temperature perceived by the body), humidification is advanta-
geous from the standpoint of both health and reduced energy con-
sumption.
In addition to such home uses, these ultrasonic humidifier units
have numerous advantages for humidification of vegetable show-
cases, preservation and growth of agricultural products, industrial
applications, etc. A wide variety of standard units are available
from TDK.
ELECTRICAL CHARACTERISTICS
The character at the end of the product number indicates the transducer’s direction of tilt.
EXAMPLE OF ATOMIZATION CHAMBER CONSTRUCTION TYPICAL TRANSDUCER INSTALLATION
TYPICAL CHARACTERISTICS OF HUMIDIFIER UNITS
VOLTAGE CHARACTERISTICS(48V) WATER TEMPERATURE CHARACTERISTICS(48V) WATER LEVEL CHARACTERISTICS
Part No. NB-59S-09S-0 NB-80E-01-H
Rated input voltage
Eac(V) 48±10%
Edc(V) 12±10%
Power consumption (W) 30±5 13.2max.
Mist output ratio (l/h) 45010
–3
min. (150+100, –50)10
–3
Ultrasonic frequency (kHz) 1600 to 1750 2350 to 2600
Normal water level (mm) 40 35
External potentiometer (k )— 10
Operating water temperature range (°C) 0 to 45 0 to 45
Water quality Drinking water Drinking water
Transducer element life (h) 10000 5000
Cooling method Water cooled Air cooled
Parallel connected operation Yes Yes
Weight (g) 60 60
Main application Various humidity control systems Microparticle applications such as for medical use
Air-flow
Mist
Mist discharge tube
Atomization chamber
Float switch
Power transformer
Ultrasonic humidifier unit
Fan moter
Transducer
Drive
circuit
Water tank
35 to 45mm
13mm
Transducer
(tilted about 7°)
The direction of
water column
Air-flow
The tilt direction of transtucer will be the
same as the direction of water column.
The arrows indicate the tilt direction
of the transducer.
Tilt directions of the transducer
NB-59S-09S Type
Transducer
+40
+20
48V+10
(
52.8V
)
+20
(
57.6V
)
+30
(
62.4V
)
–20
(
38.4V
)
–10
(
43.2V
)
–30
(
33.6V
)
–60
–40
–20
Input voltage ratio
(
%
)
Mist generation
ratio(%)
[
0%=550
(
ml/hr
)]
700
600
500
Mist output
(
ml/hr
)
Water temperature
(
˚C
)
10 20 30 40 50
600
400
200
Mist output
(
ml/hr
)
Water level
(
mm
)
30 35 40 45 50
48V series
24, 12V series
Vue de la page 1
1 2 3 4

Commentaires sur ces manuels

Pas de commentaire