TDK 5V/50A Manuel d'utilisateur Page 5

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 15
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 4
Data Sheet: Powereta
TM
iQP Series –Single Output Quarter Brick
©2005-2006 TDK Innoveta Inc.
iQP 5V/50A Datasheet 8/3/2006
(
877
)
498-0099
5/15
Electrical Data:
iQP48050A050V-000 through -0x9: 5V, 50A, 250W Output
Characteristic Min Typ Max Unit Notes & Conditions
Output Voltage Initial Setpoint 4.88 5 5.12 Vdc Vin=Vin,nom; Io=Io,max; Tc = 25˚C
Output Voltage Tolerance 4.85 5 5.15 Vdc
Over all rated input voltage, load, and
temperature conditions to end of life
Efficiency --- 91.5 --- % Vin=Vin,nom; Io=Io,max; Tc = 25˚C
Line Regulation --- 1 10* mV Vin=Vin,min to Vin,max, Io and Tc fixed
Load Regulation --- 1 10* mV Io=Io,min to Io,max, Vin and Tc fixed
Temperature Regulation --- 5 50 mV Tc=Tc,min to Tc,max, Vin and Io fixed
Output Current 5 --- 50 A
At loads less than Io,min the module will
continue to regulate the output voltage, but
the output ripple may increase slightly
Output Current Limiting Threshold --- 55 --- A Vo = 0.9*Vo,nom, Tc<Tc,max
Short Circuit Current --- 2 --- A Vo = 0.25V, Tc = 25
--- 50 100*
mVpp
Output Ripple and Noise Voltage
--- 13.5 --- mVrms
Vin=48V, Io Io,min, Tc=25˚C. Measured
across one 0.1uF, one 1.0 uF, and one
47uF ceramic capacitors, and one 1000uF
electrolytic capacitor located 2 inches away
– see input/output ripple measurement
figure; BW = 20MHz
Output Voltage Adjustment Range 80 --- 110 %Vo,nom
Vin 38V for trim-up operation
Output Voltage Sense Range --- --- 10 %Vo,nom
Dynamic Response:
Recovery Time to 10% of Peak Deviation
Transient Voltage
---
---
400
150
---
---
µS
mV
di/dt = 1A/uS, Vin=Vin,nom; load step from
50% to 75% of Io,max, Tc=25˚C with at
least one 1.0 uF, one 47uF ceramic
capacitors, and one 1000uF electrolytic
capacitor across the output terminals
Output Voltage Overshoot during startup 0 0 --- mV Vin=Vin,nom; Io=Io,max,Tc=25˚C
Switching Frequency --- 145 --- kHz Fixed
Output Over Voltage Protection 5.8* 6.1 6.5* V
External Load Capacitance 1000 ---
25,000
uF
Cext,min required for the 100% load dump.
Minimum ESR > 2 m
Isolation Capacitance --- 1000 --- pF
Isolation Resistance 15 --- --- M
Vref 1.225 V Required for trim calculation
* Engineering Estimate
Contact TDK Innoveta for applications that require additional capacitance or very low ESR
Vue de la page 4
1 2 3 4 5 6 7 8 9 10 ... 14 15

Commentaires sur ces manuels

Pas de commentaire